Sonifex Software
AVN-PXH12 Firmware Versions
3.2.2603
24 Nov 2023
Fixed
- Fixed issue when routing an AoIP stream via the Ember+ matrix.
3.1.2495
22 May 2023
Fixed
- Fixed lockup in service discovery code.
- Fixed issues with AVN-PXH12 creating multiple Ember+ consumers when connecting to an Ember+ provider.
- Fixed issues with AVN-PXH12 creating extra Ember+ consumers when disconnecting and reconnecting network port.
3.0.2260
28 July 2021
New
- New webpage UI.
- Audio metering displayed on audio routing webpage.
- Normal/Alternative selection indicated on webpage (selected channel names are highlighted).
- Normal/Alternative selection and muting of mix outputs can be changed via the audio routing webpage.
- Auto-momentary, momentary, and latching actions for soloing function (press an encoder down to enter solo mode).
- Solo safe option on mix outputs allows the corresponding output to remain unaffected whilst using the soloing function.
- The functionality of the mono/stereo button can now be selected:
- Stereo Sum - The left channel and the right channel, are routed to either the left channel or right channel.
- Mono - The left channel is routed to the left channel, or the right channel is routed to the right channel.
- Dual Mono - The left channel or the right channel, is routed to both the left and right channels.
- Multiple inputs and outputs can be added/removed from the GPIO routing grid.
Fixed
- Mute state not restored on solo safe encoder if solo still active on a different encoder.
- Changing between dual and single stream SDPs via BESS.
2.7.1992
13 November 2019
New
- SMPTE ST2110 support.
- Support for listing of redundant streams in SDPs.
- Added support for BESS (Basic Ember+ Stream Switching).
- Added SMPTE and AES-SMPTE PTP profiles.
- Added the option to use unicast delay messages instead of multicast.
AoIP Routing
PTP Profiles
2.5.1658
25 January 2019
Fixed
- AoIP streams not started correctly on network settings change.
2.5.1650
23 January 2019
New
- Added an invert option to GPIO routings.
- Multicast TTL option now available on AoIP output streams.
Fixed
- Factory reset doesn't reset network configuration.
- Auto-IP address keeps changing.
- Reducing the channel count of AoIP input streams incorrectly handled.
- AoIP input SDP information not updated.
- HTTP port number advertised incorrectly.
- Decimal part of voltage not displayed on information page.
- Momentary GPIO mute doesn't cause mute icon to be displayed.
- Removing stream doesn't work correctly if it is no longer advertised.
- Configuration window doesn't open the first time a relay output is clicked.
- Unnecessary writes to the configuration file during start up.
- Memory corruption when a remote device providing a vGPIO source is rebooted.
- Relay can't be unrouted from GPIO grid.
- The '%' character causes windows to remain open when 'Apply' is pressed.
- Streams are re-announced multiple times on start up.
- AoIP output stream not unadvertised correctly.
- No default TTL value.
Changed
-
GPIO Routing
- Removed old GPIO configuration web page.
- Added the 'GPIO Routing' web page this this provides the same functionality as the removed web pages but also has a more user-friendly interface.
2.3.1547
27 November 2018
New
-
Security Options
- A password can now be added to the devices web server within the 'Network Settings' web page, this prevents unauthorised changes to the configuration.
- The port number of the device can now be changed within the 'Network Settings' web page, this port number then needs to be provided when accessing the web server. For example if the port number is changed to 1024 the web server is then accessed using http://Device_IP_Address:1024.
Fixed
- Inter-channel phase on 'Line Output 3' incorrect by 4 samples.
- Removed buffer delay of 0 samples for AoIP streams.
- Removed signal addition when routing directly to line outputs.
- The 'Sync System Clock' PTP profile option now functions correctly.
- Various other bug fixes and stability improvements.
Changed
-
Audio Routing
- Removed the 'XLR Outputs' web page.
- Removed the 'AoIP Streams' web page.
- Removed the 'Source Selection' web page.
- Added the 'Audio Routing' web page this this provides the same functionality as the removed web pages but also has a more user-friendly interface.
1.18.1290
7 June 2018
New
- Added support for discovery of AoIP streams using SAP as well as Bonjour.
- Added GPIO support.
- Added SNMP support.
- Added support for Ember+.
- Added support for isolating ("Soloing") multiple sources to the mix simultaniously.
Fixed
- Various bug fixes and stability improvements.
1.8.935
1 November 2017
New
- Added a work-around for an issue in the RAV2SAP utility.
Fixed
- Fixed a bug with the IP address reset function.
Changed
- Updated webserver text.
1.6.893
29 September 2017
New
- Added speaker EQ to improve frequency response.
- Added XLR Output source selection - selects either local inputs, AoIP channels or Mix output.
- Added Auto-Multicast option.
- Added new webpage logos.