Signal Isolation

RB-LI2

Stereo Line Isolation Unit

The RB-LI2 stereo line isolation unit is used to isolate audio signals from inter-area ground hum loops.

RK1_logo-optimized RK2_logo-optimized

About RB-LI2

The RB-LI2 stereo line isolation unit is used to isolate audio signals from inter-area ground hum loops, which could be caused by equipment being powered by different mains power supplies, or different phases on the same supply. The input and output are connected together through a transformer, which has internal jumpers allowing the outputs to be balanced about ground.

There is also a loop-through output, so that the RB-LI2 can be inserted into a line, forming a transformer balanced distribution point.

The isolated outputs can be individually adjusted using pre-set potentiometers, accessible through the rear panel. The gain range of the stereo line isolation unit is -15dB to +13.5dB (28.5dB).

This unit is useful where audio is required to be driven over a relatively long length of cable. By isolating the signal using transformers, ground loop currents that can be present in non-isolated signals, are eradicated completely.

Typical Applications

To reduce earth hum problems, especially when the equipment at each end of your cable run is powered for either different mains power supplies or different phases of the same supply. To create an isolated distribution point, or if you need to take a feed from somewhere that doesn’t have a distribution amplifier.

Product Data

Technical Specifications

Audio Specification
Output Impedance:
<150Ω
Distortion:
0.5% THD @ 40Hz, ref +17dBu output
Common Mode Rejection:
<64dB typically
Frequency Response:
10Hz to 36kHz ±0.5dB
Output Gain Range:
-15dB to +13.5dB
Connections
Inputs:
2 x XLR 3 pin female (Balanced)
Isolated Outputs:
2 x XLR 3 pin male (Balanced)
Loop Outputs:
2 x XLR 3 pin male (Balanced)
Mains Input:
Filtered IEC, switchable 110-120V, or 220-240V, fused, 6W max
Fuse Rating:
Anti-surge fuse 100mA 20 x 5mm (230VAC)
Fuse Rating:
Anti-surge fuse 250mA 20 x 5mm (115VAC)
Equipment Type
RB-L12:
Stereo line isolation unit
Physical Specification
Dimensions (Raw):
28cm (W) x 10.8cm (D) x 4.2cm (H) (1U)
Dimensions (Raw):
11” (W) x 4.3” (D) x 1.7” (H) (1U)
Dimensions (Boxed):
36cm (W) x 20.5cm (D) x 6cm (H)
Dimensions (Boxed):
14.2” (W) x 8” (D) x 2.4” (H)
Weight:
Nett: 1.1kg  Gross: 1.5kg
Weight:
Nett: 2.4lbs Gross: 3.3lbs

Downloads & Resources

Support

Handbooks & Guides

RB-LI2 HandbookDownload ↗

Firmware

No firmware currently listed.

Firmware Notes

Full release notes for all firmware versions will appear here when available.

Brochures

Brochures, guides and supporting literature are available from the Sonifex brochures library.Visit brochures page ↗

Declarations

Access CE and UKCA declarations and other product compliance documentation.Visit declarations page ↗